Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Oper Dent ; 48(1): 51-58, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36534034

RESUMO

PURPOSE: To evaluate the effect of short curing time using a high-radiant emittance light on polymerization shrinkage vectors in different consistency bulk-fill composites (BFRCs) using micro-computed tomography. METHODS AND MATERIALS: Radiopaque zirconia fillers were homogeneously incorporated and functioned as radiopaque tracers into two regular-paste: TBFill (Tetric EvoCeram Bulk Fill) and TPFill (Tetric PowerFill), and two flowable (n=6): TBFlow (Tetric EvoFlow Bulk Fill) and TPFlow (Tetric PowerFlow) resin composites. Class I cavities (4 mm depth × 4 mm length × 4 mm width) were 3D-printed and filled in a single increment: TBFill and TBFlow were light-activated using a Bluephase Style 20i (10 seconds in high-mode); TPFill and TPFlow were light-activated using a Bluephase PowerCure (three seconds). The same adhesive system (Adhese Universal) was used for all groups. Microcomputed tomography scans were obtained before and after light-activation. Filler particle movement was identified by polymerization shrinkage vectors at five depths (from 0-4 mm): top, top-middle, middle, middle-bottom and bottom. RESULTS: TPFlow showed the lowest total vector displacement, followed by TBFlow, TBFill and TPFill, significantly different among each other (p<0.05). Generally, BFRCs showed decreased vector displacement with increased depth, and higher displacement at the top-surface (p<0.05). Qualitative analysis showed a similar pattern of vector magnitude and displacement for groups TBFill and TPFill, with displacement vectors on occlusal (top) surfaces toward the center of the restoration from the top to middle areas, and relatively limited displacement at the bottom. TBFlow and TPFlow showed more displacement on the occlusal (top). CONCLUSIONS: Short curing time with high-radiant emittance on fast-curing BFRCs was shown to be a feasible option in terms of vector displacement. Flowable BFRCs presented lower vector displacement than their regular-viscosity versions.


Assuntos
Resinas Compostas , Cárie Dentária , Humanos , Microtomografia por Raio-X , Polimerização , Teste de Materiais , Cura Luminosa de Adesivos Dentários
2.
Oper Dent ; 45(4): E167-E175, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32216725

RESUMO

CLINICAL RELEVANCE: Secondary caries are the main reason for the failure of restorations, class II being the most affected. Techniques that promote less gap percentage are important. Flowable bulk fill composites used at such locations have been shown to decrease gap formation while being a faster procedure than an incremental technique.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas , Adaptação Marginal Dentária , Humanos , Microtomografia por Raio-X
3.
Oper Dent ; 45(5): 496-505, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32101499

RESUMO

CLINICAL RELEVANCE: Shortened light curing does not affect volumetric polymerization shrinkage or cohesive tensile strength but negatively affects the shear bond strength of some bulk-fill resin composites. When performing shortened light curing, clinicians should be aware of the light output of their light-curing units. SUMMARY: Purpose: To evaluate volumetric polymerization shrinkage (VPS), shear bond strength (SBS) to dentin, and cohesive tensile strength (CTS) of bulk-fill resin composites (BFRCs) light activated by different modes.Methods and Materials: Six groups were evaluated: Tetric EvoCeram bulk fill + high mode (10 seconds; TEC H10), Tetric EvoFlow bulk fill + high mode (TEF H10), experimental bulk fill + high mode (TEE H10), Tetric EvoCeram bulk fill + turbo mode (five seconds; TEC T5), Tetric EvoFlow bulk fill + turbo mode (TEF T5), and experimental bulk fill + turbo mode (TEE T5). Bluephase Style 20i and Adhese Universal Vivapen were used for all groups. All BFRC samples were built up on human molar bur-prepared occlusal cavities. VPS% and location were evaluated through micro-computed tomography. SBS and CTS tests were performed 24 hours after storage or after 5000 thermal cycles; fracture mode was analyzed for SBS.Results: Both TEC H10 and TEE H10 presented lower VPS% than TEF H10. However, no significant differences were observed with the turbo-curing mode. No differences were observed for the same BFRC within curing modes. Occlusal shrinkage was mostly observed. Regarding SBS, thermal cycling (TC) affected all groups. Without TC, all groups showed higher SBS values for high mode than turbo mode, while with TC, only TEC showed decreased SBS from high mode to turbo modes; modes of fracture were predominantly adhesive. For CTS, TC affected all groups except TEE H10. In general, no differences were observed between groups when comparing the curing modes.Conclusions: Increased light output with a shortened curing time did not jeopardize the VPS and SBS properties of the BFRCs, although a decreased SBS was observed in some groups. TEE generally showed similar or improved values for the tested properties in a shortened light-curing time. The VPS was mostly affected by the materials tested, whereas the SBS was affected by the materials, curing modes, and TC. The CTS was not affected by the curing modes.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Humanos , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Dente Molar , Polimerização , Resistência ao Cisalhamento , Microtomografia por Raio-X
4.
Clin Diagn Lab Immunol ; 8(3): 560-3, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11329458

RESUMO

Normal assay variation associated with bDNA tests for human immunodeficiency virus type 1 (HIV-1) RNA performed at two laboratories with different levels of test experience was investigated. Two 5-ml aliquots of blood in EDTA tubes were collected from each patient for whom the HIV-1 bDNA test was ordered. Blood was stored for no more than 4 h at room temperature prior to plasma separation. Plasma was stored at -70 degrees C until transported to the Central Pennsylvania Alliance Laboratory (CPAL; York, Pa.) and to the Hershey Medical Center (Hershey, Pa.) on dry ice. Samples were stored at < or =-70 degrees C at both laboratories prior to testing. Pools of negative (donor), low-HIV-1-RNA-positive, and high-HIV-1-RNA-positive plasma samples were also repeatedly tested at CPAL to determine both intra- and interrun variation. From 11 August 1999 until 14 September 2000, 448 patient specimens were analyzed in parallel at CPAL and Hershey. From 206 samples with results of > or =1,000 copies/ml at CPAL, 148 (72%) of the results varied by < or =0.20 log(10) when tested at Hershey and none varied by >0.50 log(10). However, of 242 specimens with results of <1,000 copies/ml at CPAL, 11 (5%) of the results varied by >0.50 log(10) when tested at Hershey. Of 38 aliquots of HIV-1 RNA pool negative samples included in 13 CPAL bDNA runs, 37 (97%) gave results of <50 copies/ml and 1 (3%) gave a result of 114 copies/ml. Low-positive HIV-1 RNA pool intrarun variation ranged from 0.06 to 0.26 log(10) while the maximum interrun variation was 0.52 log(10). High-positive HIV-1 RNA pool intrarun variation ranged from 0.04 to 0.32 log(10), while the maximum interrun variation was 0.55 log(10). In our patient population, a change in bDNA HIV-1 RNA results of < or =0.50 log(10) over time most likely represents normal laboratory test variation. However, a change of >0.50 log(10), especially if the results are >1,000 copies/ml, is likely to be significant.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/genética , HIV-1/isolamento & purificação , RNA Viral/análise , Ensaio de Amplificação de Sinal de DNA Ramificado/normas , Infecções por HIV/virologia , Humanos , RNA Viral/genética , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...